Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)3
Power loss6W
Current limiting class1
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Surge current capacity0.25kA
Over voltage category3
Frequency50/60 Hz
Voltage typeAC
Release characteristicC
Disconnection characteristicUndelayed
With interlocking deviceNo
Connectable conductor cross section solid-core35 - 35mm²
Number of protected poles3
Pollution degree2
Rated current6A
Rated voltage400V
Rated insulation voltage Ui500V
Leakage current typeAC
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Flush-mounted installationNo
Built-in depth72mm
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94155 | Compact RCBO 3P C6 6KA AC/0.3 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Power loss

6W

Current limiting class

1

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Surge current capacity

0.25kA

Over voltage category

3

Frequency

50/60 Hz

Voltage type

AC

Release characteristic

C

Disconnection characteristic

Undelayed

With interlocking device

Connectable conductor cross section solid-core

35 .. 35mm²

Number of protected poles

3

Pollution degree

2

Rated current

6A

Rated voltage

400V

Rated insulation voltage Ui

500V

Leakage current type

AC

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Width in number of modular spacings

3

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Flush-mounted installation

Built-in depth

72mm

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.