Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Surge current capacity0.25kA
Rated current14.68A
Rated voltage400V
Current limiting class1
Voltage typeAC
Width in number of modular spacings4
Pollution degree2
Leakage current typeAC
Built-in depth72mm
Rated fault current0.03A
Rated insulation voltage Ui500V
Release characteristicC
Over voltage category3
Degree of protection (IP)IP20
Power loss32W
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section multi-wired35 - 35mm²
Number of protected poles4
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)4
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94170

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Surge current capacity

0.25kA

Rated current

14.68A

Rated voltage

400V

Current limiting class

1

Voltage type

AC

Width in number of modular spacings

4

Pollution degree

2

Leakage current type

AC

Built-in depth

72mm

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Release characteristic

C

Over voltage category

3

Degree of protection (IP)

IP20

Power loss

32W

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Number of protected poles

4

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

4

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.