Technical specifications

Built-in depth72mm
Release characteristicC
Rated voltage400V
Frequency50/60 Hz
Pollution degree2
Current limiting class1
Surge current capacity0.25kA
Width in number of modular spacings4
Voltage typeAC
Over voltage category3
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-26kA
Number of protected poles4
Power loss13W
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Flush-mounted installationNo
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated current9.8A
Rated fault current0.03A
Leakage current typeAC
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94171 | Compact RCBO 4P C13 6KA AC/0.03 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Rated voltage

400V

Frequency

50/60 Hz

Pollution degree

2

Current limiting class

1

Surge current capacity

0.25kA

Width in number of modular spacings

4

Voltage type

AC

Over voltage category

3

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Number of protected poles

4

Power loss

13W

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Flush-mounted installation

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated current

9.8A

Rated fault current

0.03A

Leakage current type

AC

Number of poles (total)

4