Number of poles (total)4
Number of protected poles4
Rated insulation voltage Ui500V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current32A
Rated fault current0.3A
Current limiting class1
Leakage current typeAC
Power loss32W
Rated short-circuit breaking capacity according to EN 610096kA
Voltage typeAC
Rated short-circuit breaking capacity according to IEC 60947-26kA
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Surge current capacity0.25kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Over voltage category3
Release characteristicC
Disconnection characteristicUndelayed
Flush-mounted installationNo
With interlocking deviceNo
Pollution degree2
Built-in depth72mm
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94180 | Compact RCBO 4P C32 6KA AC/0.3 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Rated insulation voltage Ui

500V

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated fault current

0.3A

Current limiting class

1

Leakage current type

AC

Power loss

32W

Rated short-circuit breaking capacity according to EN 61009

6kA

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Width in number of modular spacings

4

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Over voltage category

3

Release characteristic

C

Disconnection characteristic

Undelayed

Flush-mounted installation

With interlocking device

Pollution degree

2

Built-in depth

72mm

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version