Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles1
Rated insulation voltage Ui500V
Leakage current typeA
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current10A
Rated short-circuit breaking capacity according to EN 610096kA
Current limiting class3
Power loss10W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Voltage typeAC
Frequency50/60 Hz
Surge current capacity0.25kA
Release characteristicC
With interlocking deviceNo
Over voltage category3
Concurrently switching neutral conductorYes
Pollution degree2
Ambient temperature during operating-25 - 40°C
Built-in depth72mm
Flush-mounted installationNo
Width in number of modular spacings2
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94306 | Compact RCBO 1P+N C10 6KA A/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

1

Rated insulation voltage Ui

500V

Leakage current type

A

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

10A

Rated short-circuit breaking capacity according to EN 61009

6kA

Current limiting class

3

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Frequency

50/60 Hz

Surge current capacity

0.25kA

Release characteristic

C

With interlocking device

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Built-in depth

72mm

Flush-mounted installation

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.