Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Over voltage category3
Current limiting class3
Leakage current typeA
Rated fault current0.3A
Rated current3.76A
Surge current capacity0.25kA
Rated voltage230V
Built-in depth72mm
Release characteristicC
Rated insulation voltage Ui500V
Frequency50/60 Hz
Pollution degree2
Power loss20W
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles1
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceNo
Disconnection characteristicUndelayed
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94318

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Over voltage category

3

Current limiting class

3

Leakage current type

A

Rated fault current

0.3A

Rated current

3.76A

Surge current capacity

0.25kA

Rated voltage

230V

Built-in depth

72mm

Release characteristic

C

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Pollution degree

2

Power loss

20W

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

1

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Disconnection characteristic

Undelayed

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.