  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current typeA
Surge current capacity0.25kA
Rated voltage230V
Rated current32A
Rated fault current0.3A
Voltage typeAC
Rated insulation voltage Ui500V
Built-in depth72mm
Release characteristicC
Current limiting class3
Over voltage category3
Power loss32W
Pollution degree2
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Number of protected poles1
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Frequency50/60 Hz
Disconnection characteristicUndelayed
Width in number of modular spacings2
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94320

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current type

A

Surge current capacity

0.25kA

Rated voltage

230V

Rated current

32A

Rated fault current

0.3A

Voltage type

AC

Rated insulation voltage Ui

500V

Built-in depth

72mm

Release characteristic

C

Current limiting class

3

Over voltage category

3

Power loss

32W

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Number of protected poles

1

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

With interlocking device