Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current6A
Built-in depth72mm
Voltage typeAC
Rated voltage230V
Rated fault current0.03A
Release characteristicC
Leakage current typeA
Current limiting class3
Over voltage category3
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core35 - 35mm²
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP20
Pollution degree2
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Number of protected poles2
Power loss6W
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Number of poles (total)2
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94325

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

6A

Built-in depth

72mm

Voltage type

AC

Rated voltage

230V

Rated fault current

0.03A

Release characteristic

C

Leakage current type

A

Current limiting class

3

Over voltage category

3

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP20

Pollution degree

2

Frequency

50/60 Hz

Concurrently switching neutral conductor

Number of protected poles

2

Power loss

6W

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Number of poles (total)

2

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.