Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated fault current0.03A
Leakage current typeA
Current limiting class3
Power loss16W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Voltage typeAC
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Release characteristicC
With interlocking deviceNo
Over voltage category3
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Pollution degree2
Flush-mounted installationNo
Built-in depth72mm
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94327 | Compact RCBO 2P C16 6KA A/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated fault current

0.03A

Leakage current type

A

Current limiting class

3

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Voltage type

AC

Frequency

50/60 Hz

Concurrently switching neutral conductor

Release characteristic

C

With interlocking device

Over voltage category

3

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Flush-mounted installation

Built-in depth

72mm

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20