Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated voltage230V
Release characteristicC
Width in number of modular spacings2
Rated current7.34A
Rated short-circuit breaking capacity according to IEC 60947-210kA
Surge current capacity0.25kA
Over voltage category3
Built-in depth72mm
Number of protected poles2
Frequency50/60 Hz
Degree of protection (IP)IP20
Power loss32W
Pollution degree2
Concurrently switching neutral conductorNo
Rated fault current0.03A
Rated insulation voltage Ui500V
Current limiting class3
Leakage current typeA
Number of poles (total)2
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Anti-nuisance tripping versionNo
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94330

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated voltage

230V

Release characteristic

C

Width in number of modular spacings

2

Rated current

7.34A

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Surge current capacity

0.25kA

Over voltage category

3

Built-in depth

72mm

Number of protected poles

2

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Power loss

32W

Pollution degree

2

Concurrently switching neutral conductor

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Current limiting class

3

Leakage current type

A

Number of poles (total)

2

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Anti-nuisance tripping version

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.