Number of poles (total)2
Rated insulation voltage Ui500V
Rated voltage230V
Rated short-circuit breaking capacity according to EN 610096kA
Rated current6A
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Rated fault current0.03A
Number of protected poles2
Power loss6W
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Surge current capacity3kA
Voltage typeAC
Over voltage category3
Frequency50/60 Hz
Concurrently switching neutral conductorNo
With interlocking deviceNo
Disconnection characteristicShort-time delayed
Built-in depth72mm
Anti-nuisance tripping versionYes
Release characteristicC
Flush-mounted installationNo
Pollution degree2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95805 | Compact RCBO 2P C6 6KA AIR/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated fault current

0.03A

Number of protected poles

2

Power loss

6W

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Surge current capacity

3kA

Voltage type

AC

Over voltage category

3

Frequency

50/60 Hz

Concurrently switching neutral conductor

With interlocking device

Disconnection characteristic

Short-time delayed

Built-in depth

72mm

Anti-nuisance tripping version

Release characteristic

C

Flush-mounted installation

Pollution degree

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.