Technical specifications

Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Number of protected poles2
Rated fault current0.03A
Rated voltage230V
Rated insulation voltage Ui500V
Leakage current typeA
Current limiting class3
Power loss10W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated current10A
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Voltage typeAC
Disconnection characteristicShort-time delayed
Frequency50/60 Hz
Width in number of modular spacings2
Release characteristicC
Over voltage category3
Surge current capacity3kA
Pollution degree2
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Built-in depth72mm
Anti-nuisance tripping versionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95806 | Compact RCBO 2P C10 6KA AIR/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Rated fault current

0.03A

Rated voltage

230V

Rated insulation voltage Ui

500V

Leakage current type

A

Current limiting class

3

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated current

10A

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Disconnection characteristic

Short-time delayed

Frequency

50/60 Hz

Width in number of modular spacings

2

Release characteristic

C

Over voltage category

3

Surge current capacity

3kA

Pollution degree

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Built-in depth

72mm

Anti-nuisance tripping version