Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category3
Pollution degree2
Surge current capacity3kA
Current limiting class3
Width in number of modular spacings2
Rated insulation voltage Ui500V
Power loss20W
Release characteristicC
Voltage typeAC
Rated voltage230V
Built-in depth72mm
Frequency50/60 Hz
Rated fault current0.03A
Leakage current typeA
Number of protected poles2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Rated current20A
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to EN 610096kA
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Anti-nuisance tripping versionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95808

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category

3

Pollution degree

2

Surge current capacity

3kA

Current limiting class

3

Width in number of modular spacings

2

Rated insulation voltage Ui

500V

Power loss

20W

Release characteristic

C

Voltage type

AC

Rated voltage

230V

Built-in depth

72mm

Frequency

50/60 Hz

Rated fault current

0.03A

Leakage current type

A

Number of protected poles

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Rated current

20A

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.