Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current0.03A
Rated current5.76A
Release characteristicC
Built-in depth72mm
Rated voltage230V
Voltage typeAC
Rated insulation voltage Ui500V
Leakage current typeA
Current limiting class3
Surge current capacity3kA
Over voltage category3
Pollution degree2
Width in number of modular spacings2
Power loss25W
Frequency50/60 Hz
Degree of protection (IP)IP20
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicShort-time delayed
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Number of protected poles2
Anti-nuisance tripping versionYes
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Number of poles (total)2
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95809

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current

0.03A

Rated current

5.76A

Release characteristic

C

Built-in depth

72mm

Rated voltage

230V

Voltage type

AC

Rated insulation voltage Ui

500V

Leakage current type

A

Current limiting class

3

Surge current capacity

3kA

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

2

Power loss

25W

Frequency

50/60 Hz

Degree of protection (IP)

IP20

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Short-time delayed

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of protected poles

2

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Number of poles (total)

2

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.