Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated current2.12A
Rated voltage230V
Built-in depth72mm
Over voltage category3
Leakage current typeA
Surge current capacity0.25kA
Release characteristicC
Width in number of modular spacings2
Frequency50/60 Hz
Current limiting class3
Rated insulation voltage Ui500V
Power loss6W
Rated fault current0.3A
Pollution degree2
Degree of protection (IP)IP20
Number of protected poles2
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorNo
Disconnection characteristicUndelayed
Connectable conductor cross section solid-core35 - 35mm²
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94335

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated current

2.12A

Rated voltage

230V

Built-in depth

72mm

Over voltage category

3

Leakage current type

A

Surge current capacity

0.25kA

Release characteristic

C

Width in number of modular spacings

2

Frequency

50/60 Hz

Current limiting class

3

Rated insulation voltage Ui

500V

Power loss

6W

Rated fault current

0.3A

Pollution degree

2

Degree of protection (IP)

IP20

Number of protected poles

2

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.