Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.56A
Number of protected poles2
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Over voltage category3
Power loss16W
Frequency50/60 Hz
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section multi-wired35 - 35mm²
Current limiting class3
Rated voltage230V
Rated fault current0.3A
Leakage current typeA
Rated insulation voltage Ui500V
Pollution degree2
Built-in depth72mm
Degree of protection (IP)IP20
Release characteristicC
Voltage typeAC
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94337

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.56A

Number of protected poles

2

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Over voltage category

3

Power loss

16W

Frequency

50/60 Hz

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Current limiting class

3

Rated voltage

230V

Rated fault current

0.3A

Leakage current type

A

Rated insulation voltage Ui

500V

Pollution degree

2

Built-in depth

72mm

Degree of protection (IP)

IP20

Release characteristic

C

Voltage type

AC

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.