Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Rated fault current0.3A
Rated insulation voltage Ui500V
Power loss20W
Rated current20A
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Rated short-circuit breaking capacity according to EN 610096kA
Frequency50/60 Hz
Voltage typeAC
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorNo
Number of protected poles2
Width in number of modular spacings2
Release characteristicC
Over voltage category3
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Pollution degree2
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94338 | Compact RCBO 2P C20 6KA A/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated fault current

0.3A

Rated insulation voltage Ui

500V

Power loss

20W

Rated current

20A

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated short-circuit breaking capacity according to EN 61009

6kA

Frequency

50/60 Hz

Voltage type

AC

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Number of protected poles

2

Width in number of modular spacings

2

Release characteristic

C

Over voltage category

3

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Pollution degree

2

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.