Rated current8.24A
Voltage typeAC
Built-in depth72mm
Rated voltage400V
Pollution degree2
Width in number of modular spacings4
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Over voltage category3
Release characteristicC
Frequency50/60 Hz
Surge current capacity3kA
Current limiting class1
Power loss10W
Rated fault current0.03A
Leakage current typeA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionYes
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section solid-core35 - 35mm²
Disconnection characteristicShort-time delayed
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Number of protected poles4
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95816

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

8.24A

Voltage type

AC

Built-in depth

72mm

Rated voltage

400V

Pollution degree

2

Width in number of modular spacings

4

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Over voltage category

3

Release characteristic

C

Frequency

50/60 Hz

Surge current capacity

3kA

Current limiting class

1

Power loss

10W

Rated fault current

0.03A

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Disconnection characteristic

Short-time delayed

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Number of protected poles

4

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.