Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicC
Voltage typeAC
Rated voltage400V
Rated current10.88A
Over voltage category3
Rated insulation voltage Ui500V
Power loss20W
Leakage current typeA
Pollution degree2
Rated fault current0.03A
Current limiting class1
Width in number of modular spacings4
Degree of protection (IP)IP20
Surge current capacity3kA
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core35 - 35mm²
Number of protected poles4
Anti-nuisance tripping versionYes
Concurrently switching neutral conductorNo
Number of poles (total)4
Ambient temperature during operating-25 - 40°C
Disconnection characteristicShort-time delayed
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Flush-mounted installationNo
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95818

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Voltage type

AC

Rated voltage

400V

Rated current

10.88A

Over voltage category

3

Rated insulation voltage Ui

500V

Power loss

20W

Leakage current type

A

Pollution degree

2

Rated fault current

0.03A

Current limiting class

1

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Surge current capacity

3kA

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

35 .. 35mm²

Number of protected poles

4

Anti-nuisance tripping version

Concurrently switching neutral conductor

Number of poles (total)

4

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Short-time delayed

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

With interlocking device