Technical specifications

Number of poles (total)3
Rated insulation voltage Ui500V
Number of protected poles3
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Current limiting class1
Rated fault current0.03A
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated current16A
Voltage typeAC
Leakage current typeA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Power loss16W
Rated short-circuit breaking capacity according to EN 610096kA
Surge current capacity0.25kA
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
Pollution degree2
Release characteristicC
Flush-mounted installationNo
Built-in depth72mm
Over voltage category3
Width in number of modular spacings3
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94347 | Compact RCBO 3P C16 6KA A/0.03 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Current limiting class

1

Rated fault current

0.03A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated current

16A

Voltage type

AC

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Power loss

16W

Rated short-circuit breaking capacity according to EN 61009

6kA

Surge current capacity

0.25kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Release characteristic

C

Flush-mounted installation

Built-in depth

72mm

Over voltage category

3

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

With interlocking device