Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current7.47A
Current limiting class1
Connectable conductor cross section multi-wired35 - 35mm²
Frequency50/60 Hz
Degree of protection (IP)IP20
Pollution degree2
Built-in depth72mm
Rated short-circuit breaking capacity according to IEC 60947-26kA
Voltage typeAC
Surge current capacity0.25kA
Rated fault current0.03A
Width in number of modular spacings3
Over voltage category3
Rated insulation voltage Ui500V
Leakage current typeA
Power loss13W
Number of protected poles3
Release characteristicC
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Rated voltage400V
Flush-mounted installationNo
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94351

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

7.47A

Current limiting class

1

Connectable conductor cross section multi-wired

35 .. 35mm²

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Pollution degree

2

Built-in depth

72mm

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Surge current capacity

0.25kA

Rated fault current

0.03A

Width in number of modular spacings

3

Over voltage category

3

Rated insulation voltage Ui

500V

Leakage current type

A

Power loss

13W

Number of protected poles

3

Release characteristic

C

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Rated voltage

400V

Flush-mounted installation

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.