Technical specifications

Number of poles (total)2
Rated insulation voltage Ui500V
Number of protected poles2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated fault current0.3A
Leakage current typeA
Current limiting class3
Power loss16W
Rated short-circuit breaking capacity according to EN 610096kA
Surge current capacity3kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicSelective
Frequency50/60 Hz
Voltage typeAC
Concurrently switching neutral conductorNo
Over voltage category3
With interlocking deviceNo
Release characteristicC
Pollution degree2
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Anti-nuisance tripping versionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95847 | Compact RCBO 2P C16 6KA AS/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated fault current

0.3A

Leakage current type

A

Current limiting class

3

Power loss

16W

Rated short-circuit breaking capacity according to EN 61009

6kA

Surge current capacity

3kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Selective

Frequency

50/60 Hz

Voltage type

AC

Concurrently switching neutral conductor

Over voltage category

3

With interlocking device

Release characteristic

C

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Anti-nuisance tripping version