Technical specifications

Number of poles (total)2
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated current25A
Power loss25W
Current limiting class3
Rated fault current0.3A
Rated short-circuit breaking capacity according to EN 610096kA
Rated voltage230V
Leakage current typeA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicSelective
Surge current capacity3kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
With interlocking deviceNo
Over voltage category3
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Pollution degree2
Built-in depth72mm
Anti-nuisance tripping versionYes
Degree of protection (IP)IP20
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95849 | Compact RCBO 2P C25 6KA AS/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Power loss

25W

Current limiting class

3

Rated fault current

0.3A

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated voltage

230V

Leakage current type

A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Selective

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Pollution degree

2

Built-in depth

72mm

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²