Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.24A
Built-in depth72mm
Rated voltage400V
Voltage typeAC
Surge current capacity0.25kA
Leakage current typeA
Rated fault current0.3A
Release characteristicC
Width in number of modular spacings4
Rated insulation voltage Ui500V
Over voltage category3
Pollution degree2
Current limiting class1
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-26kA
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Power loss6W
Number of protected poles4
With interlocking deviceNo
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)4
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94375

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.24A

Built-in depth

72mm

Rated voltage

400V

Voltage type

AC

Surge current capacity

0.25kA

Leakage current type

A

Rated fault current

0.3A

Release characteristic

C

Width in number of modular spacings

4

Rated insulation voltage Ui

500V

Over voltage category

3

Pollution degree

2

Current limiting class

1

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Power loss

6W

Number of protected poles

4

With interlocking device

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

4

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.