Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current0.3A
Release characteristicC
Rated insulation voltage Ui500V
Voltage typeAC
Built-in depth72mm
Rated current11.52A
Rated voltage400V
Frequency50/60 Hz
Surge current capacity0.25kA
Connectable conductor cross section solid-core35 - 35mm²
Number of poles (total)4
Flush-mounted installationNo
Over voltage category3
Number of protected poles4
Rated short-circuit breaking capacity according to IEC 60947-26kA
Current limiting class1
With interlocking deviceNo
Leakage current typeA
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Power loss25W
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Pollution degree2
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94379

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current

0.3A

Release characteristic

C

Rated insulation voltage Ui

500V

Voltage type

AC

Built-in depth

72mm

Rated current

11.52A

Rated voltage

400V

Frequency

50/60 Hz

Surge current capacity

0.25kA

Connectable conductor cross section solid-core

35 .. 35mm²

Number of poles (total)

4

Flush-mounted installation

Over voltage category

3

Number of protected poles

4

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Current limiting class

1

With interlocking device

Leakage current type

A

Concurrently switching neutral conductor

Width in number of modular spacings

4

Power loss

25W

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA