Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Rated current14.68A
Rated voltage400V
Voltage typeAC
Built-in depth72mm
Over voltage category3
Width in number of modular spacings4
Current limiting class1
Frequency50/60 Hz
Degree of protection (IP)IP20
Leakage current typeA
Surge current capacity0.25kA
Power loss32W
Pollution degree2
Rated fault current0.3A
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94380

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Rated current

14.68A

Rated voltage

400V

Voltage type

AC

Built-in depth

72mm

Over voltage category

3

Width in number of modular spacings

4

Current limiting class

1

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Leakage current type

A

Surge current capacity

0.25kA

Power loss

32W

Pollution degree

2

Rated fault current

0.3A

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Flush-mounted installation

Concurrently switching neutral conductor

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.