Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.12A
Built-in depth72mm
Voltage typeAC
Release characteristicC
Surge current capacity0.25kA
Leakage current typeAC
Rated insulation voltage Ui500V
Rated voltage230V
Over voltage category3
Current limiting class3
Rated fault current0.03A
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Power loss10W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of protected poles2
Frequency50/60 Hz
Connectable conductor cross section multi-wired35 - 35mm²
Pollution degree2
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
With interlocking deviceNo
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95026

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.12A

Built-in depth

72mm

Voltage type

AC

Release characteristic

C

Surge current capacity

0.25kA

Leakage current type

AC

Rated insulation voltage Ui

500V

Rated voltage

230V

Over voltage category

3

Current limiting class

3

Rated fault current

0.03A

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

10W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of protected poles

2

Frequency

50/60 Hz

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

With interlocking device

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C