Technical specifications

Rated insulation voltage Ui500V
Number of poles (total)2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current16A
Number of protected poles2
Power loss16W
Leakage current typeAC
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
Voltage typeAC
With interlocking deviceNo
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 40°C
Width in number of modular spacings2
Built-in depth72mm
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95027 | Compact RCBO 2P C16 10KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

16A

Number of protected poles

2

Power loss

16W

Leakage current type

AC

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

Voltage type

AC

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Built-in depth

72mm

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version