Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current typeAC
Rated current4.9A
Built-in depth72mm
Rated voltage230V
Surge current capacity0.25kA
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category3
Pollution degree2
Rated fault current0.03A
Release characteristicC
Width in number of modular spacings2
Voltage typeAC
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-215kA
Power loss13W
Concurrently switching neutral conductorNo
Frequency50/60 Hz
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Number of poles (total)2
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95031

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current type

AC

Rated current

4.9A

Built-in depth

72mm

Rated voltage

230V

Surge current capacity

0.25kA

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

3

Pollution degree

2

Rated fault current

0.03A

Release characteristic

C

Width in number of modular spacings

2

Voltage type

AC

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Power loss

13W

Concurrently switching neutral conductor

Frequency

50/60 Hz

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Number of poles (total)

2

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.