Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Rated fault current0.3A
Rated current4.56A
Rated insulation voltage Ui500V
Rated voltage230V
Voltage typeAC
Leakage current typeAC
Current limiting class3
Surge current capacity0.25kA
Built-in depth72mm
Frequency50/60 Hz
Power loss16W
Width in number of modular spacings2
Degree of protection (IP)IP20
Over voltage category3
Number of protected poles2
Pollution degree2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-215kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95037

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Rated fault current

0.3A

Rated current

4.56A

Rated insulation voltage Ui

500V

Rated voltage

230V

Voltage type

AC

Leakage current type

AC

Current limiting class

3

Surge current capacity

0.25kA

Built-in depth

72mm

Frequency

50/60 Hz

Power loss

16W

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Over voltage category

3

Number of protected poles

2

Pollution degree

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.