Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated insulation voltage Ui500V
Rated current16A
Rated impulse withstand voltage Uimp4kV
Rated fault current0.3A
Leakage current typeAC
Current limiting class3
Power loss16W
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Surge current capacity0.25kA
Voltage typeAC
Release characteristicC
Frequency50/60 Hz
Pollution degree2
Concurrently switching neutral conductorNo
With interlocking deviceNo
Over voltage category3
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Width in number of modular spacings2
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Built-in depth72mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95037 | Compact RCBO 2P C16 10KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Leakage current type

AC

Current limiting class

3

Power loss

16W

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Voltage type

AC

Release characteristic

C

Frequency

50/60 Hz

Pollution degree

2

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Built-in depth

72mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.