Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.56A
Built-in depth72mm
Voltage typeAC
Rated voltage110V
Rated insulation voltage Ui500V
Release characteristicC
Rated fault current0.03A
Surge current capacity0.25kA
Leakage current typeA
Current limiting class3
Over voltage category3
Power loss16W
Width in number of modular spacings2
Number of protected poles2
Degree of protection (IP)IP20
Frequency50/60 Hz
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95227MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.56A

Built-in depth

72mm

Voltage type

AC

Rated voltage

110V

Rated insulation voltage Ui

500V

Release characteristic

C

Rated fault current

0.03A

Surge current capacity

0.25kA

Leakage current type

A

Current limiting class

3

Over voltage category

3

Power loss

16W

Width in number of modular spacings

2

Number of protected poles

2

Degree of protection (IP)

IP20

Frequency

50/60 Hz

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²