Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Rated fault current0.03A
Rated current13A
Current limiting class3
Leakage current typeA
Power loss13W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity according to EN 6100910kA
Voltage typeAC
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Concurrently switching neutral conductorNo
Pollution degree2
With interlocking deviceNo
Frequency50/60 Hz
Release characteristicC
Width in number of modular spacings2
Over voltage category3
Ambient temperature during operating-25 - 40°C
Built-in depth72mm
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95231 | Compact RCBO 2P C13 10KA A/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Rated current

13A

Current limiting class

3

Leakage current type

A

Power loss

13W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Concurrently switching neutral conductor

Pollution degree

2

With interlocking device

Frequency

50/60 Hz

Release characteristic

C

Width in number of modular spacings

2

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Built-in depth

72mm

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²