Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated current4.9A
Over voltage category3
Degree of protection (IP)IP20
Built-in depth72mm
Leakage current typeA
Connectable conductor cross section solid-core35 - 35mm²
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Pollution degree2
Release characteristicC
Connectable conductor cross section multi-wired35 - 35mm²
Surge current capacity0.25kA
Ambient temperature during operating-25 - 40°C
Current limiting class3
Power loss13W
With interlocking deviceNo
Number of protected poles2
Rated insulation voltage Ui500V
Rated fault current0.03A
Rated voltage110V
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95231MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated current

4.9A

Over voltage category

3

Degree of protection (IP)

IP20

Built-in depth

72mm

Leakage current type

A

Connectable conductor cross section solid-core

35 .. 35mm²

Frequency

50/60 Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Pollution degree

2

Release characteristic

C

Connectable conductor cross section multi-wired

35 .. 35mm²

Surge current capacity

0.25kA

Ambient temperature during operating

-25 .. 40°C

Current limiting class

3

Power loss

13W

With interlocking device

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Rated voltage

110V

Width in number of modular spacings

2

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.