Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.3A
Leakage current typeA
Rated current10A
Current limiting class3
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss10W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Voltage typeAC
Surge current capacity0.25kA
Width in number of modular spacings2
Release characteristicC
With interlocking deviceNo
Frequency50/60 Hz
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree2
Ambient temperature during operating-25 - 40°C
Built-in depth72mm
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95236 | Compact RCBO 2P C10 10KA A/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Leakage current type

A

Rated current

10A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Voltage type

AC

Surge current capacity

0.25kA

Width in number of modular spacings

2

Release characteristic

C

With interlocking device

Frequency

50/60 Hz

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Built-in depth

72mm

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.