Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Pollution degree2
Width in number of modular spacings2
Built-in depth72mm
Rated voltage230V
Leakage current typeA
Rated current20A
Rated fault current0.3A
Surge current capacity0.25kA
Over voltage category3
Rated insulation voltage Ui500V
Current limiting class3
Release characteristicC
Degree of protection (IP)IP20
Number of poles (total)2
Number of protected poles2
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Power loss20W
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Frequency50/60 Hz
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95238

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Pollution degree

2

Width in number of modular spacings

2

Built-in depth

72mm

Rated voltage

230V

Leakage current type

A

Rated current

20A

Rated fault current

0.3A

Surge current capacity

0.25kA

Over voltage category

3

Rated insulation voltage Ui

500V

Current limiting class

3

Release characteristic

C

Degree of protection (IP)

IP20

Number of poles (total)

2

Number of protected poles

2

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Power loss

20W

Concurrently switching neutral conductor

Anti-nuisance tripping version

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.