Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage230V
Number of poles (total)2
Rated fault current0.1A
Rated current20A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of protected poles2
Leakage current typeA
Power loss20W
Current limiting class3
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Voltage typeAC
Surge current capacity0.25kA
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Release characteristicC
With interlocking deviceNo
Built-in depth72mm
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95788 | Compact RCBO 2P C20 10KA A/0,1 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Number of poles (total)

2

Rated fault current

0.1A

Rated current

20A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of protected poles

2

Leakage current type

A

Power loss

20W

Current limiting class

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Release characteristic

C

With interlocking device

Built-in depth

72mm

Width in number of modular spacings

2

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.