  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Built-in depth72mm
Rated current7.34A
Release characteristicC
Rated voltage230V
Over voltage category3
Flush-mounted installationNo
Rated fault current0.1A
Connectable conductor cross section multi-wired35 - 35mm²
Leakage current typeA
Current limiting class3
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Rated insulation voltage Ui500V
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Number of protected poles2
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Power loss32W
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Frequency50/60 Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95790

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated current

7.34A

Release characteristic

C

Rated voltage

230V

Over voltage category

3

Flush-mounted installation

Rated fault current

0.1A

Connectable conductor cross section multi-wired

35 .. 35mm²

Leakage current type

A

Current limiting class

3

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Rated insulation voltage Ui

500V

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Number of protected poles

2

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Power loss

32W

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Frequency

50/60 Hz

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.