Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.9A
Rated voltage230V
Voltage typeAC
Built-in depth72mm
Rated fault current0.1A
Release characteristicC
Pollution degree2
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Leakage current typeA
Degree of protection (IP)IP20
Width in number of modular spacings2
Over voltage category3
Current limiting class3
Frequency50/60 Hz
Number of protected poles2
Power loss13W
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95791

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.9A

Rated voltage

230V

Voltage type

AC

Built-in depth

72mm

Rated fault current

0.1A

Release characteristic

C

Pollution degree

2

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Leakage current type

A

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Over voltage category

3

Current limiting class

3

Frequency

50/60 Hz

Number of protected poles

2

Power loss

13W

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.