Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)3
Leakage current typeA
Disconnection characteristicUndelayed
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Surge current capacity0.25kA
Voltage typeAC
Release characteristicC
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss10W
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Rated voltage230V
Rated current10A
Rated fault current0.03A
Width in number of modular spacings3
With interlocking deviceNo
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Built-in depth72mm
Over voltage category3
Ambient temperature during operating-25 - 40°C
Frequency50/60 Hz
Connectable conductor cross section solid-core35 - 35mm²
Pollution degree2
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95246 | Compact RCBO 3P C10 10KA A/0,03 3M 230V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Leakage current type

A

Disconnection characteristic

Undelayed

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Voltage type

AC

Release characteristic

C

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

10W

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Rated voltage

230V

Rated current

10A

Rated fault current

0.03A

Width in number of modular spacings

3

With interlocking device

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Built-in depth

72mm

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Frequency

50/60 Hz

Connectable conductor cross section solid-core

35 .. 35mm²

Pollution degree

2

Connectable conductor cross section multi-wired

35 .. 35mm²