Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class3
Surge current capacity0.25kA
Built-in depth72mm
Rated fault current0.03A
Rated insulation voltage Ui500V
Voltage typeAC
Release characteristicB
Rated voltage230V
Rated current6A
Leakage current typeA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core35 - 35mm²
Number of protected poles1
Disconnection characteristicUndelayed
Pollution degree2
Flush-mounted installationNo
Number of poles (total)2
With interlocking deviceNo
Width in number of modular spacings2
Rated short-circuit breaking capacity according to EN 610096kA
Degree of protection (IP)IP20
Power loss6W
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Over voltage category3
Frequency50/60 Hz
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95105

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class

3

Surge current capacity

0.25kA

Built-in depth

72mm

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Voltage type

AC

Release characteristic

B

Rated voltage

230V

Rated current

6A

Leakage current type

A

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

35 .. 35mm²

Number of protected poles

1

Disconnection characteristic

Undelayed

Pollution degree

2

Flush-mounted installation

Number of poles (total)

2

With interlocking device

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Degree of protection (IP)

IP20

Power loss

6W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Over voltage category

3

Frequency

50/60 Hz

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C