Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated fault current0.03A
Leakage current typeA
Rated voltage230V
Power loss25W
Rated current25A
Current limiting class3
Over voltage category3
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Frequency50/60 Hz
Pollution degree2
Disconnection characteristicUndelayed
With interlocking deviceNo
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
Anti-nuisance tripping versionNo
Voltage typeAC
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Built-in depth72mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95109 | Compact RCBO 1P+N B25 6KA A/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated fault current

0.03A

Leakage current type

A

Rated voltage

230V

Power loss

25W

Rated current

25A

Current limiting class

3

Over voltage category

3

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Pollution degree

2

Disconnection characteristic

Undelayed

With interlocking device

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

Anti-nuisance tripping version

Voltage type

AC

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Built-in depth

72mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.