Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicB
Rated current1.15A
Built-in depth72mm
Voltage typeAC
Rated voltage230V
Rated insulation voltage Ui500V
Rated fault current0.3A
Frequency50/60 Hz
Current limiting class3
Degree of protection (IP)IP20
Over voltage category3
Anti-nuisance tripping versionNo
Leakage current typeA
Surge current capacity0.25kA
Connectable conductor cross section solid-core35 - 35mm²
Power loss6W
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorYes
Disconnection characteristicUndelayed
Number of poles (total)2
Flush-mounted installationNo
Pollution degree2
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95115

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

B

Rated current

1.15A

Built-in depth

72mm

Voltage type

AC

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Frequency

50/60 Hz

Current limiting class

3

Degree of protection (IP)

IP20

Over voltage category

3

Anti-nuisance tripping version

Leakage current type

A

Surge current capacity

0.25kA

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

6W

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Number of poles (total)

2

Flush-mounted installation

Pollution degree

2

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Width in number of modular spacings

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.