Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated current2.32A
Rated fault current0.3A
Leakage current typeA
Release characteristicB
Surge current capacity0.25kA
Rated voltage230V
Rated insulation voltage Ui500V
Voltage typeAC
Number of protected poles1
Power loss10W
Width in number of modular spacings2
Over voltage category3
Degree of protection (IP)IP20
Frequency50/60 Hz
Pollution degree2
Current limiting class3
Number of poles (total)2
With interlocking deviceNo
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Disconnection characteristicUndelayed
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95116

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated current

2.32A

Rated fault current

0.3A

Leakage current type

A

Release characteristic

B

Surge current capacity

0.25kA

Rated voltage

230V

Rated insulation voltage Ui

500V

Voltage type

AC

Number of protected poles

1

Power loss

10W

Width in number of modular spacings

2

Over voltage category

3

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Pollution degree

2

Current limiting class

3

Number of poles (total)

2

With interlocking device

Flush-mounted installation

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.