Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles1
Rated voltage230V
Current limiting class3
Surge current capacity0.25kA
Voltage typeAC
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Frequency50/60 Hz
Power loss20W
With interlocking deviceNo
Rated insulation voltage Ui500V
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP20
Release characteristicB
Built-in depth72mm
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Pollution degree2
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Over voltage category3
Rated current20A
Rated fault current0.3A
Leakage current typeA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95118 | Compact RCBO 1P+N B20 6KA A/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

1

Rated voltage

230V

Current limiting class

3

Surge current capacity

0.25kA

Voltage type

AC

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Frequency

50/60 Hz

Power loss

20W

With interlocking device

Rated insulation voltage Ui

500V

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP20

Release characteristic

B

Built-in depth

72mm

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Pollution degree

2

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Over voltage category

3

Rated current

20A

Rated fault current

0.3A

Leakage current type

A

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.