  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4.12A
Release characteristicB
Rated insulation voltage Ui500V
Rated voltage230V
Leakage current typeA
Rated fault current0.03A
Voltage typeAC
Built-in depth72mm
Current limiting class3
Over voltage category3
Surge current capacity0.25kA
Power loss10W
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section solid-core35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings2
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Flush-mounted installationNo
Number of protected poles2
Disconnection characteristicUndelayed
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Pollution degree2
Number of poles (total)2
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95126

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4.12A

Release characteristic

B

Rated insulation voltage Ui

500V

Rated voltage

230V

Leakage current type

A

Rated fault current

0.03A

Voltage type

AC

Built-in depth

72mm

Current limiting class

3

Over voltage category

3

Surge current capacity

0.25kA

Power loss

10W

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Flush-mounted installation

Number of protected poles

2

Disconnection characteristic

Undelayed

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Pollution degree

2

Number of poles (total)

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C