Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current10A
Current limiting class3
Power loss10W
Rated fault current0.03A
Rated short-circuit breaking capacity according to EN 610096kA
Leakage current typeA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Concurrently switching neutral conductorNo
Release characteristicB
Frequency50/60 Hz
With interlocking deviceNo
Over voltage category3
Width in number of modular spacings2
Pollution degree2
Built-in depth72mm
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95126 | Compact RCBO 2P B10 6KA A/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

10A

Current limiting class

3

Power loss

10W

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Concurrently switching neutral conductor

Release characteristic

B

Frequency

50/60 Hz

With interlocking device

Over voltage category

3

Width in number of modular spacings

2

Pollution degree

2

Built-in depth

72mm

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²