Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current16A
Leakage current typeA
Current limiting class3
Power loss16W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Frequency50/60 Hz
Surge current capacity0.25kA
Release characteristicB
Voltage typeAC
Concurrently switching neutral conductorNo
Over voltage category3
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Pollution degree2
Width in number of modular spacings2
Flush-mounted installationNo
Built-in depth72mm
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95127 | Compact RCBO 2P B16 6KA A/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

16A

Leakage current type

A

Current limiting class

3

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Frequency

50/60 Hz

Surge current capacity

0.25kA

Release characteristic

B

Voltage type

AC

Concurrently switching neutral conductor

Over voltage category

3

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Width in number of modular spacings

2

Flush-mounted installation

Built-in depth

72mm

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²