Technical specifications

Rated voltage230V
Rated fault current0.03A
Voltage typeAC
Rated insulation voltage Ui500V
Rated current7.34A
Leakage current typeA
Release characteristicB
Surge current capacity0.25kA
Built-in depth72mm
Width in number of modular spacings2
Current limiting class3
Pollution degree2
Over voltage category3
Rated short-circuit breaking capacity according to IEC 60947-210kA
With interlocking deviceNo
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Power loss32W
Number of poles (total)2
Concurrently switching neutral conductorNo
Frequency50/60 Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95130

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Rated fault current

0.03A

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

7.34A

Leakage current type

A

Release characteristic

B

Surge current capacity

0.25kA

Built-in depth

72mm

Width in number of modular spacings

2

Current limiting class

3

Pollution degree

2

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

With interlocking device

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Power loss

32W

Number of poles (total)

2

Concurrently switching neutral conductor

Frequency

50/60 Hz