Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.3A
Rated current10A
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Disconnection characteristicUndelayed
With interlocking deviceNo
Voltage typeAC
Release characteristicB
Power loss10W
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Over voltage category3
Surge current capacity0.25kA
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Pollution degree2
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95136 | Compact RCBO 2P B10 6KA A/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Rated current

10A

Leakage current type

A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

With interlocking device

Voltage type

AC

Release characteristic

B

Power loss

10W

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Over voltage category

3

Surge current capacity

0.25kA

Width in number of modular spacings

2

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Pollution degree

2

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.